SCADA
 
Indisoft Web Studio is very powerful Automation software that has all required tools for developing Human Machine Interfaces (HMI), Supervisory Control and Data Acquisition (SCADA) systems, instrumentation and control applications. Indisoft Web Studio applications can be operable on Windows NT, 2000, XP, CE and CE .NET operating systems and support all Microsoft .NET, OPC, DDE, ODBC, XML, and ActiveX industrial standarts.
 
General Features 

    * Windows NT/2000/XP operating sytems for development version
    * Windows NT/2000/XP or  Windows CE 3.x/CE.NET 4.x operating systems for run time version
    * Integrated OPC Client and OPC Server modules with PC Browse
    * DDE Client and DDE Server modules
    * TCP/IP Client and TCP/IP Server modules for tag sharing and redundant system structure
    * Communication driver support for more than 150 different devices (PLC, Controller…etc)
    * Standart protocols (For ex: DELTA, Nais/Panasonic, Allen-Bradley, Siemens, GE-Fanuc, MODBUS RTU/ASCII, DeviceNet, Profibus, Interbus…etc)
    * Graphic ScreensEasy editing to the complicated interfaces with “Point and click”, “drag and drop” support
    * 15 different type graphic support (can be importable)
    * Ready to use prepared more than 40 dynamic effect (shadowing, foreground and bachground colors, blinking, fulness, rotation, motion, size changing, text, animation…etc)
    * Object-oriented structure provides reusability of screens and objects
    * Big symbol bank

Alarms

    * Alarm management system provides oriantations for various alarms to the screens, e-mail, web browser, archieve groups
    * Alarm mesaages can be built desired structure and can be reachable group and tag name.
    * Alarmc can be backup to the printer, file or database
    * Filtering, sorting, color sorting features for visual simplicity 

TREND

    * Online and historical monitoring of process values

Receipt and report

    * User defined flexible recipe groups
    * User defined configurable graphic and text reports

Input/Output

    * Driver for more than 150 different devices
    * OPC (Client & Server) support
    * Various PC control packets support

General

    * Advanced math library supports more than 100 standart function
    * Flexible and easy to use programming with script language
    * Multilevel security contains internet and intranet
    * Supports Microsoft .NET, OPC, DDE, ODBC, XML, SOAP, and ActiveX..etc. industrial standarts
    * Real-time auto language conversation support


Features – Product Structure

    * Common development interfaces for Windows XP/ 2000/NT and CE/CE.NET run-time platforms
    * Remote Management and Broadcasting
    * On-line configuration
    * Object-oriented database
    * Object-oriented graphic screen and Object browser
    * Microsoft Windows XP look and feel
    * Explorer-Still Project and document management
    * Microsoft Windows .NET compatible
    * MFC (Microsoft Foundation Classes) library
    * Easy integration with API Toolkits

Features – Application

    * FULL-FEATURED Web Thin Client solution (visualization and commands, security system, Online/History alarms, On-line/History trend, ActiveX support, translation, etc.)
    * FULL-FEATURED WinCE run-time environment (CEView)
    * Auto e-mail support (SMTP)
    * Dial-up connection interface
    * Scaleable security level (Unlimitted Group and user)
    * Filness efect (gradient color)
    * Real-time language conversation tool
    * Communication Drives: Windows NT/2000/XP and Windows CE/CE.NET
    * More than 150 driver for OPC Client and Server
    * TCP/IP Client and Server
    * DDE Client and Server
    * ODBC Interface
    * ActiveX container
       (Windows NT/2000/XP and WindowsCE/CE.NET)
    * Editable dynamic object library
    * Built-in script language (Noneed programming knowledge)
    * Alarm and trend backup
    * On-line alarm and trend
    * Recipe (XML and TXT)
    * Report (RTF and TXT)
    * Sorting and programming module (events)
    * PC base control system integration over shared database
    * Debug Tools: Database Spy and LogWin (Run-time systems local and remote maintenance)  PacketsDEVELOPMENT LICENCE

      (TOGETHER WITH ONE PCS RUN-TIME AND ONE PCS WEB SESSION):
Model ExplanationInduSoft-NT512000D Advanced Server (512,000Tags, unlimited drivers)
    * InduSoft-NT64000D Control Room (64,000Tags, 8drivers)
    * InduSoft-NT4000D Operator Workstation (4,000Tags, 5drivers)
    * InduSoft-NT1500D Local Interface for Windows NT/2000/XP (1500Tags, 3drivers)
    * InduSoft-CE1500D CEView standard for Windows CE (CE View)(1500Tags, 3drivers)

Development Only
(without RUN-Time license)

    * InduSoft-NT300D NTView PRO for Windows NT/2000/XP (300Tags, 1drivers)
    * InduSoft-CE300D CEView Lite Plus for Windows CE (CE View)(300Tags, 1drivers)

Development Only
(without RUN-Time license)

    * InduSoft-gateway InduSoft Gateway only ADDITIONAL RUN-TIME LICENCESInduSoft-NT512000R Advanced Server Run-time (512,000Tags, unlimited drivers)
    * InduSoft-NT64000R Control Room Run-time (64,000Tags, 8drivers)
    * InduSoft-NT4000R Operator Workstation Run-time (4,000Tags, 5drivers)
    * InduSoft-NT1500R Local Interface for Windows NT/2000/XP Run-time
(1500Tags, 3drivers)
    * InduSoft-CE1500R CEView standard for Windows CE Run-time (CE View)
(1500Tags, 3drivers)
    * InduSoft-NT300R NTView PRO for Windows NT/2000/XP Run-time (300Tags, 1drivers)
    * InduSoft-CE300R CEView Lite Plus for Windows CE Run-time (300Tags, 1drivers)
    * InduSoft-NT150R Lite Interface for Windows NT/2000/XP Run-time (150Tags, 1drivers)
    * InduSoft-CE150R CEView Lite for Windows CE Run-time (150Tags, 1drivers)


InduSoft Web Studio v7.0 SP1 + P2 SCADA Software
Getting Started Guide (Quick Start Guide) IWS v7.0
User Manuel
InduSoft Web Studio v6.1 + Service Pack 6 + Patch 2
Service Pack 6+Patch2 for InduSoft Web Studio v6.1
Patch 3 for InduSoft Web Studio v6.1 + Service Pack 6
Kullanım Klavuzu (User Guide)
Başlarken (Getting Started Manuel)
www.indusoft.com
     
     
    << Geri
   
 
Fabrika Aygıtları Sistem Teknolojisi A.Ş.